DSC POWERSERIES PC1616 User Manual

Page 10

Advertising
background image

[402] Downloading Computer Phone Number (32-digits)

[403] Downloading Access Code
Enter 4 or 6-digit code

This code identifies the downloading computer to the panel.
The downloading access code prevents unauthorized access to the panel.
This code must match the code programmed in the downloading file before the
panel will allow remote or local DLS connection. Enter a new downloading
access code to disable downloading.

[404] Panel Identification Code

This code identifies the panel to the downloading computer.
See section [403]

Enter 6 decimal places

[499][Installer Code][499] Initiate PC-Link
Enter [499][Installer Code][499]

Special Installer Functions

[000] Keypad Programming

Note: This programming must be done at each keypad

[001]-[004] Zone Definitions

Enter the number corresponding to the zone definitions required.The keypad
will beep rapidly 3 times and move to the next step. If an invalid number is
entered the keypad will revert to the default setting (option [1]).

Press [#] to exit the section.

I

D

II___II___II___II___II___II___II___II___II___II___II___II___II___II___II___I

I___II___II___II___II___II___II___II___II___II___II___II___II___II___II___II___I

Default XXXXXX

I___II___II___II___II___II___I

Default XXXXXX

I___II___II___II___II___II___I

Enter section# for the following features

[900]
[902]
[903]
[904]

Panel Version ([

][8][Installer Code][900])

Module Supervision Reset ([

][8][Installer Code][902])

Module Supervision Field ([

][8][Installer Code][903])

Wireless Module Placement Test ([

][8][Installer Code][904])

Enter section#, Installer Code section# for the following features

[990] INSTALLER CODE [990]
[991] INSTALLER CODE [991]
[993] INSTALLER CODE [993]
[995] INSTALLER CODE [995]
[996] INSTALLER CODE [996]
[997] INSTALLER CODE [997]
[999] INSTALLER CODE [999]

Installer Lockout Enable
Installer Lockout Disable
Restore Alt.Comm. Factory Defaults
Restore Escort 5580 Factory Defaults
Restore PC5132 Factory Defaults
Restore PC5400 Factory Defaults
Restore Panel Factory Defaults

[0]
[1]
[2]
[3]
[4]
[5]

Slot Address (0-8) for partition, 1-8 for slot
Function key Assignment (00-32)
Function key Assignment (00-32)
Function key Assignment (00-32)
Function key Assignment (00-32)
Function key Assignment (00-32)

Slot Address

Key

1

Key

2

Key

3

Key

4

Key

5

ICON
LED

Defaults

11

03

04

06

14

16

Full Message
Defaults

18

03

04

06

14

16

Keypad 1
Keypad 2
Keypad 3
Keypad 4
Keypad 5
Keypad 6
Keypad 7
Keypad 8

KEYPAD FUNCTION KEY DEFINITIONS

00 Null Key (Key not used)
01 Partition 1 Select
02 Partition 2 Select
03 Stay Arm
04 Away Arm
05 [

][9] No entry arm

06 [

][4] Chime On/Off

07 [

][6][----][4]System Test

08 [

][1] Bypass Mode

09 [

][2] Trouble display

10 [

][3] Alarm memory

11 [

][5] User programming

12 [

][6] User functions

13 Command output 1 [

71]

14 Command output 1 [

72] Sensor

Reset
15 General voice prompted help
16 [

][0] Quick Exit

17 [

][0] Activate Stay/Away

18 Identified voice prompted
help
19 Command output 3 [

73]

20 Not used
21 Command output 4 [

74]

22 Active camera monitor
selection
23 Bypass Recall
24 Bypass Group Recall
25 Not Used
26 Time Programming
27 Partition 3 Select
28 Partition 4 Select
29 Partition 5 Select
30 Partition 6 Select
31 Partition 7 Select
32 Partition 8 Select

[001] Zone 1-16 Definitions ALL Models

00 Null Zone (not used)
01 Delay 1
02 Delay 2
03 Instant
04 Interior
05 Interior, Stay/Away
06 Delay, Stay/Away
07 Delayed 24-hr Fire

(Hard-wired)

08 Standard 24-hr Fire

(Hard-wired)

09 24-hr Supervisory
10 24-hr Supervisory Bu
11 24-hr Burglary
12 24-hr Holdup
13 24-hr Gas
14 24-hr Heat
15 24-hr Medical
16 24-hr Panic
17 24-hr Emergency
18 24-hr Sprinkler
19 24-hr Water
20 24-hr Freeze
21 24-hr Latching

Tamper

22 Momentary Keyswitch

arm

23 Maintained Key-

switch Arm

24 Future Use
25 Interior Delay
26 25-hr non-alarm
27 Delayed 24-hr Water

Flow

28 Instant 24-hr Water

Flow

29 Auto-verified Fire
30 Fire Supervisory
31 Day zone
32 24-hr Bell/Buzzer
33 Push to set
34 Final Door set
35 Instant Stay, Away
36 24-hr Non latching

Tamper

37 Night Zone
87 Delayed 24-hr Fire

(Wireless)

88 24-hr Fire (Wireless)

Def

Def

01 I__II__I Zone 1
03 I__II__I Zone 2
03 I__II__I Zone 3
03 I__II__I Zone 4
04 I__II__I Zone 5
04 I__II__I Zone 6
04 I__II__I Zone 7
04 I__II__I Zone 8

00 I__II__I Zone 9
00 I__II__I Zone 10
00 I__II__I Zone 11
00 I__II__I Zone 12
00 I__II__I Zone 13
00 I__II__I Zone 14
00 I__II__I Zone 15
00 I__II__I Zone 16

[002] Zone 17-32 Definitions PC1864 & PC1832

Def

Def

00 I__II__I Zone 17
00 I__II__I Zone 18
00 I__II__I Zone 19
00 I__II__I Zone 20
00 I__II__I Zone 21
00 I__II__I Zone 22
00 I__II__I Zone 23
00 I__II__I Zone 24

00 I__II__I Zone 25
00 I__II__I Zone 26
00 I__II__I Zone 27
00 I__II__I Zone 28
00 I__II__I Zone 29
00 I__II__I Zone 30
00 I__II__I Zone 31
00 I__II__I Zone 32

[003] Zone 33-48 Definitions PC1864 Only

Def

Def

00 I__II__I Zone 33
00 I__II__I Zone 34
00 I__II__I Zone 35
00 I__II__I Zone 36
00 I__II__I Zone 37
00 I__II__I Zone 38
00 I__II__I Zone 39
00 I__II__I Zone 40

00 I__II__I Zone 41
00 I__II__I Zone 42
00 I__II__I Zone 43
00 I__II__I Zone 44
00 I__II__I Zone 45
00 I__II__I Zone 46
00 I__II__I Zone 47
00 I__II__I Zone 48

[004] Zone 49-64 Definitions PC1864 Only

Def

Def

00 I__II__I Zone 49
00 I__II__I Zone 50
00 I__II__I Zone 51
00 I__II__I Zone 52
00 I__II__I Zone 53
00 I__II__I Zone 54
00 I__II__I Zone 55
00 I__II__I Zone 56

00 I__II__I Zone 57
00 I__II__I Zone 58
00 I__II__I Zone 59
00 I__II__I Zone 60
00 I__II__I Zone 61
00 I__II__I Zone 62
00 I__II__I Zone 63
00 I__II__I Zone 64

Advertising
This manual is related to the following products: