Testing:

•

Power up system

•

Program options as required (See Programming Section on reverse side)

Note: For advanced programming refer to the PC1616/1832/1864 Reference manual

•

Violate, then restore zones

•

Verify correct Reporting Codes are sent to the Central Station

Troubleshooting:

LCD5500 LCD Programmable-Message Keypad

•

Press [

✱][2] to view a trouble condition.

•

The trouble light will flash and the LCD will display the first trouble condition present.

•

Use the arrow keys to scroll through all trouble conditions present.

NOTE: When additional information is available for a specific trouble condition a [

✱] will appear on the display.

Press the [

✱] key to view the additional information

LED Keypads, LCD Fixed Message Keypads

•

Press [

✱][2] to view a trouble condition.

•

The trouble light will flash.

•

Refer to the Trouble Summary chart below to determine the trouble condition(s) present.

Trouble Summary:

Light [1]

✱ Service Required - Press [1] for more information

[1] Low Battery
[2] Bell Circuit
[3] General System Trouble
[4] General system Tamper
[5] Module Supervision
[6] RF Jam Detected
[7] PC5204 Low Battery
[8] PC5204 AC Failure

Light [2] AC Trouble

Light [3] Telephone Line Trouble

Light [4] Failure to Communicate

Light [5]

✱ Zone Fault -Press [5] for more information

Light [6]

✱ Zone Tamper - Press [6] for more information

Light [7]

✱ Wireless Device Low Battery - Press [7] for more information

Light [8] Loss of Time or Date