[310]-[311] Partition Identifier Codes
Enter a 6 digit Maintenance Code

[350] – Communicator Format Options

This section determines the communication format used for central
station reporting. From the chart listed below program the 2-digit num-
ber for the desired format for the first and second telephone number

[367] – Opening/Closing Call Direction Options

The first toggle option in this section is used to enable/disable opening/
closing reporting for partition 1. To enable opening/closing reporting
turn option [1] ON. Configure the options as required and press [#] to
exit

.

[377] Communication Variables

NOTE: For UL Installations, the Entry Delay plus the Communications
Delay must not exceed 60 seconds.

[380] – First Communicator Option Codes

[381] – Second Communicator Option Codes

The 3rd toggle option in this section is used to enable/disable auto-
matic SIA reporting. The 5th toggle option is used to enable/disable
automatic Contact ID reporting. Configure the options as required and
press [#] to exit.

NOTE:If the automatic SIA or automatic Contact ID reporting formats
are not used, reporting codes must be programmed. To program
reporting codes refer to the PowerSeries PC1616/1832/1864 Refer-
ence Manual which can be downloaded from the DSC web site at

www.dsc.com

[382] – Third Communicator Option Codes

The 4th toggle option in this section is used to enable/disable Call
Waiting Cancel. Configure the options as required and press [#] to exit.
NOTE:A Call Waiting Cancel on a Non Call Waiting line will prevent
successful connection to the central station.

[701] – First International Options Codes

Option 7 in this section Selects Battery Charge Options.
Select ON for 7 Ahr and 14 Ahr batteries (700 mA charge rate)
Select OFF for Standard 4 Ahr batteries (400 mA charge rate)

[310 System Acct. Code

I___II___II___II___II___II___I

[311] Partition 1 Acct. Code

I___II___II___II___I

Def

Enter 2 digits From Chart Below

04
04

I___II___I
I___II___I

NOTE: 3rd Phone Number follows the format of the

1st Phone Number

01 20BPS, 1400 Hz Handshake
02 20BPS, 2300 Hz Handshake
03 DTMF Contact ID
04 SIA FSK
05 Pager
06 Residential Dial

07 10BPS, 1400 Hz Handshake
08 10BPS, 2300 Hz Handshake
09 Private Line
10 Scantronics 4-8-1 Fast Slo
12 Robofon
13 CESA 200

Opt

Default

Description

1

I__I

ON

1st Telephone Number

OFF

Disabled

2

I__I

ON

2nd Telephone Number

OFF

Disabled

5

I__I

ON

Alternate Communicator

OFF

Disabled

Def

Enter 3 digits as indicated below

003 I___II___II___I

003 I___II___II___I

003 I___II___II___I

000 I___II___II___I
030 I___II___II___I
010 I___II___II___I

030 I___II___II___I

030 I___II___II___I
007 I___II___II___I

030 I___II___II___I

000 I___II___II___I

Swinger Shutdown
(Alarms and Rest.
Swinger Shutdown
(Tamper and Rest.
Swinger Shutdown
(Maint. and Rest.
Communication Delay
AC Failure Comm Delay
TLM Trouble Delay

Test Transmission Cycle
(land line)
Not Used
Zone low Battery
Transmission Delay
Delinquency Transmis-
sion Cycle
Communications
Cancelled Window

(001-014 Transmissions)

(001-014 Transmissions,
000=disabled)
(001-014 Transmissions,
000=disabled)
(000-255 seconds)
(001-255 minutes)
No. of checks req’d (003-
255)
(001-255 days/minutes)

(000-255 days)

(000-255 days/hours)

(000-255 minutes)

NOTE: Option 1 is defaulted to 001 for CP-01 Installations

Option 4 is defaulted to 030 for CP-01 Installations
Option 11 is defaulted to 005 for CP-01 Installations

Opt

Default

Description

1

I__I

ON

Communications Enabled

OFF

Communications Disabled

2

I__I

ON

Restorals on Bell Time-out

OFF

Restorals Follow Zones

3

I__I

ON

Pulse Dialing

OFF

DTMF Dialing

5

I__I

ON

3rd Telephone Number Enabled

OFF

3rd Telephone Number Disabled

8

I__I

ON

Delinquency Follows Zone Activity (Hours)

OFF

Delinquency Follows Arming (Days)

Opt

Default

Description

3

I__I

ON

SIA Sends Programmed Reporting Codes

OFF

SIA Sends Automatic Reporting Codes

5

I__I

ON

Contact ID Uses Programmed Reporting
Codes

OFF

Contact ID Uses Automatic Reporting Codes

Opt

Default

Description

4

I__I

ON

Call Waiting Cancel Enabled

OFF

Call Waiting Cancel Disabled

5

I__I

ON

T-Link Interface Enabled

OFF

T-Link Interface Disabled

Opt

Default

Description

7

I__I

ON

High Current Battery Charge (700mA)

OFF

Standard Battery Charge Rate (400mA)