When single 10-inch vertical venting is used( refer to Ulus. B. below), the duct work from the

dryer to the outside outlet cannot exceed 20 feet. This calculation of 20 feet compensates or allows
for the use of a maximum of only two (2) elbows creating the 180® (turned downward) outside
outlet.

VERTICAL SINGLE DRYER VENTING

lUus. B.

see vewv mw

isecTVH mn

Uo-X

Л • и

J

яттнАот

-голтоист

ноте Лг OPSHNQ MUST К TWO 01 HCt€5 LAWCB9 ГНАМ OUCT <AU Tf€ W*f ЛтЛЯ»

OUCT wtat ae СЕНтЕяео гнв

опша

For a 10-inch horizontal run where a maximum of one (1) elbow is used (refer to Ulus. C
below); the duct work from the dryer outlet should not exceed 50 feet. A 10-inch horizontal

duct where (3) elbows (including outside outlet protection) are used cannot exceed 30 feet in
length.

Ulus. C.

HORIZONTAL SINGLE DRYER

VENTING 10 INCH DUCTING

sofeer HAxHjH^

ноте A.- OPSHNO MUST ae TWO Ф ic>cs

lmgep

than

rw

duct

mu

way

ллемо

»c OUCT MUST ee сентеко

witmn

ths

okunq

.

If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the
cross area of the duct work must be increased in proportion to the number of elbows or duct run
added.

IMPORTANT: For extended duct work runs, the cross section area of the duct work can

only be increased to an extent. When the duct work approaches the
maximum limits noted in this manual, a professional heating venting
air conditioning (HVAC) firm should be consulted for proper venting
information.