American Dryer Corp. AD-385 User Manual
Page 25
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
IMPORTANT; Input connection wking must be sized properly to handle the dryer's current
draw. This current/amperage information is printed on the dryers data label.
2.) Three Phase (3 0) Model (Hookup) Connections
The only electrical input connections to the dryer are the 3-phase (3 0) power leads
(L1,L2,L3) and ground.
These connections are made at the power distribution block located inside the electric
service box. The ground coimection is made at the ground lug also provided in this service
box.
GROUND
TYPICAL
STRAIN
RELIEF
Providing local codes permit, power to the dryer can be made by the use of a flexible U.L.
listed cord/pigtail, or the dryer can be hard wired directly to the service breaker. In ALL
cases, a strain relief must be used where the wiring enters the dryer and service box.
IMPORTANT: Input connection wiring must be sized properly to handle the dryer's current
draw. This current/amperage information is printed on the dryers data label.
NOTES: A. Fuse ratings (as listed in chart on page xx) are dual element-time delay-current
limiting, class RKl or RK5 only.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/
verify correct breaker size according to appliance amp draw rating and type of
breaker used.
C. Circuit breakers for 3 0 dryers must be 3-pole type.
D. Electrical Amperage and Fusing Listing
21