IMPORTANT; Input connection wking must be sized properly to handle the dryer's current

draw. This current/amperage information is printed on the dryers data label.

2.) Three Phase (3 0) Model (Hookup) Connections

The only electrical input connections to the dryer are the 3-phase (3 0) power leads

(L1,L2,L3) and ground.

These connections are made at the power distribution block located inside the electric

service box. The ground coimection is made at the ground lug also provided in this service
box.

GROUND

TYPICAL

STRAIN

RELIEF

Providing local codes permit, power to the dryer can be made by the use of a flexible U.L.
listed cord/pigtail, or the dryer can be hard wired directly to the service breaker. In ALL
cases, a strain relief must be used where the wiring enters the dryer and service box.

IMPORTANT: Input connection wiring must be sized properly to handle the dryer's current

draw. This current/amperage information is printed on the dryers data label.

NOTES: A. Fuse ratings (as listed in chart on page xx) are dual element-time delay-current

limiting, class RKl or RK5 only.

B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/

verify correct breaker size according to appliance amp draw rating and type of

breaker used.

C. Circuit breakers for 3 0 dryers must be 3-pole type.

D. Electrical Amperage and Fusing Listing