AEG 860 D User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Wall

mounting

Installation steps for exhaust air operation

1.

Hold the installation template (with readable lettering) on the

wall,

noting the distance between the upper edge of the hob

and the iower edge of the fume extractor hood!

(Electric/gas cookers

650 mm)

(oil and coal cookers

min.

700 mm).

2. Mark out and drill the

8 mm dia.

holes. Insert the wall plugs

and mount the wall rail

(Fig. EO/3).

The wall rail can be horizontally aligned by shifting the sliding

elements.

Important! Oniy use the suppiied 5 x 60 mm screws to DIN

7996!

3.

Mount the fume extractor hood in the wall rail and centrally

align about the cooker hob.

4.

Insert the chimney retaining plate

(Fig. EO/4)

in the fume

extractor hood (cutout for exhaust air hose) so that both

angles (above) face forwards

(Fig. EO/4).

Fix the chimney

retaining plate with 6 8 x 4 0 mm wall plugs and 8 x 4 0 mm

screws on the wall.

5.

Connect the exhaust air hose (without sleeve) of the fume

extractor hood directly to the wall box behind or directly con­

nect 125 mm dia. exhaust air hose to the fume extractor hood

and run on.

36

Advertising
This manual is related to the following products: