Additional

installation

work for return

air operation

38

Installation steps same as for exhaust air operation under
points 1 —4

Further installation steps:

5. Slide guide piece

(Fig. EO/9)

on to chimney cover plate

(Fig. EO/4).

6.

Fix exchaust air hose on guide piece with 125 mm dia. hose

clip.

7. Fix chimney equalizer as under exhaust air..

8.

Unclip the ventilation grille

(Fig. EO/8)

from the chimney

cover plate and, after pulling off the foil (double adhesive

tape)

(Fig. EO/7),

slide the chimney cover plate from the

front on to the fume extractor hood until it engages the hol­

ders on the RFI and LH sides

(Fig. EO/10).

9. Fix chimney cover plate

(Fig. EO/2)

laterally with 4

2.9 x 6.5

mm sheet metal screws on the chimney retaining plate.

10.

Clip the ventilation grille laterally (on the RH and LH sides)

on the guide piece

(Fig. EO/9).

Important! Lamination position obliquely downwards!

Unless this has been done as preparation work, 2 KL 600 car­
bon filters (E-No. 610 899 470) (for your own account from our

range of special accessories) must be inserted for return air
operation!