Safety instructions

For the

electrical

installer

For the kitchen

furniture

installer

28

Arrangement of the protective contact plug socket inside the

chimney cover plate (Fig. EO/2) confers two advantages:

1. The plug socket is not visible.

2. You can easily de-energize the appliance where necessary

by unplugging it.

For the necessary fixed connection, the fume extractor hood

may be connected only by an electrical installer registered with

the electricity board covering your area. An isolating device is to

be provided on the fixed wiring side.

Switches with a contact opening of more than 3 mm also apply

as isolating devices.

These include line protection switches,

fuses, and contactors (VDE 0730, s. 7, Part 1 ).

Connection

220 V~ via fixed supply lead with protective contact plug (Eu­

ropa version).

240 V~ via fixed supply lead (UK).

(Fixed connection to be made only by an approved electrical

installer)

This appliance complies with the radio interference suppression

requirements of EC Directives 76/889 EC and 82/499 EC.

The exhaust air may not be introduced into a smoke flue or
exhaust gas chimney.

Introduction of the exhaust air into a shaft used for ventilation

of the installation spaces of firerooms is not permitted.

If the exhaust air is introduced into a non-operational smoke

flue or exhaust gas chimney, it is advisable to seek the con­
sent of the competent chimney-sweep.
The official exhaust air guidance regulations are basically to

be complied with.

During operation as an exhaust air appliance, an adequate

supply air opening of approximately the same size as the ex­

haust air opening is to be ensured.

According to the Provincial Building Regulations, the joint op­

eration of fume extractor hoods and chimney-linked fire­

places, such as coal- or oil-fired ovens and gas heaters, in the

same space is subject to specific restrictions.

In such spaces, the Fireplace Regulations only allow an under­

pressure of max. 0.04 mbar.

The safe joint operation of chimney-linked appliances and

fume extractor hoods is only guaranteed if space and/or
dwelling (space/air interaction) are externally ventilated by a
suitable supply air opening of around 500—600 cm2 and an

underpressure thereby avoided when the fume extractor hood

is running.