Operating instructions, Locating heater, Warning: never use a fork lift truck type cylinder – Desa 35-R User Manual

Page 5: Warning: never use a flame for gas leak testing

Advertising
background image

www.desatech.com

117296-01A

5

The installer must inform the owner/operator of

this appliance that precautions must be taken to

protect the appliance from physical damage.
This appliance produces radiant heat. Therefore,

it must be located at least 6 feet away from

any propane/LP gas container and must not be

directed toward any propane/LP gas container

within 20 feet.
The heater must be installed in a location such that

it will not be exposed directly to water spray, rain

and/or dripping water.
Use of this heater in a draft/windy area decreases

its efficiency. If possible, operate the unit in a

draft free area.

CONNECTING TO GAS SUPPLY

This model may be connected to a self-contained

propane/LP gas supply system using the hose and

regulator assembly supplied with the appliance

OR, it may be connected to a permanently installed

propane/LP gas supply system.
If connected to a self-contained propane/LP

gas supply system, the hose assembly must be

inspected prior to each use of the heater. If it is

evident that there is excessive abrasion or wear or

if the hose is cut, it must be replaced prior to the

heater being put into operation.

WARNING: Never use a fork

lift truck type cylinder.

The connection to a propane/LP cylinder must be

made in a well ventilated area using the regulator

and hose assembly supplied with the appliance.

DO NOT attempt to adjust this regulator. It has

been preset at the factory to provide safe and

proper operation of the appliance. Use a 7/8" open

end wrench to connect the POL fitting (supplied

with the propane/LP regulator) to the propane/LP

cylinder. Turn the POL nut in a counterclockwise

direction (left hand thread) until tight. DO NOT

use pipe compound on POL threads.
The heater must be located at least 6 feet away

from any propane/LP cylinder and must not be

directed toward any propane/LP cylinder within

20 feet. If more than one heater is used, they

and the supply cylinders must be separated by at

least 20 feet.

The gas supply must be turned off at the propane/

LP supply cylinder when the heater is not in use.
When the heater is to be stored indoors, the con-

nection between the propane/LP supply cylinder

and the heater must be disconnected and the

cylinder removed from the heater and stored in

accordance with Chapter 5 of the Standard for

the Storage and Handling of Liquefied Petroleum

Gases ANSI/NFPA 58

.

If connected to a permanently installed propane/

LP supply system, the system requires the use

of a two-stage gas regulator assembly which is

normally provided by your propane/LP dealer as

part of the propane/LP supply system. Consult with

your local propane/LP dealer for details concern-

ing proper equipment and installation.
Piping must be clean and free from scale or

burrs.

WARNING: Never use a flame

for gas leak testing.

OPERATING

INSTRUCTIONS

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

CAUTION: This appliance

is hot during normal operation,

avoid physical contact.

CAUTION: Do not place

clothing or other combustible

materials on this appliance.

DO NOT operate this heater if any part has been

under water. Call a qualified service technician to

inspect the appliance and to replace any part of

the control system or gas control valve which has

been under water.