Troubleshooting – Desa 35-R User Manual

Page 7

Advertising
background image

www.desatech.com

117296-01A

7

SYMPTOM

Burner fails to light

Pilot lights but goes out when

automatic control valve button

is released

Burn rate is low

Burner lights but goes out when

button is released

POSSIBLE CAUSE

1. Gas supply valve closed

2. Excess-flow check valve

closed

3. Blockage in burner orifice

4. Piezo ignition system not

sparking

1. Not enough warm-up time

2. Low gas pressure

3. Thermocouple loose or needs

to be replaced

4. Automatic control valve needs

to be replaced

1. Plugged gas orifices

2. Low gas pressure

3. Low fuel supply

1. Loose wires on tip over

switch

2. Loose or broken lead wire

3. Loose or mislocated thermo-

couple wire

4. Defective thermocouple

5. Defective control

6. Defective tip over switch

REMEDY

1. Open gas supply valve slowly

2. Close propane supply valve

on propane tank and reopen

slowly

3. Replace burner orifice

4. Assure ignitor electrode gap is

5.0 mm (0.195 in). Check wire

lead for damage Replace piezo

ignitor and/or ignitor electrode

as necessary. Do not bend elec-

trode, this may cause breakage

1. Relight, hold automatic control

valve button in 45 seconds

2. Check for proper gas supply

3. Tighten connection or replace

thermocouple

4. Replace automatic control

valve

1. Replace gas orifice

2. Check gas supply; check

regulator output

3. Consult gas supplier to deter-

mine adequate supply. Tank

could be empty

1. Tighten wires on tip over

switch

2. Tighten or repair wire

3. Tighten thermocouple. Make

sure thermocouple is located

correctly between reverbera-

tor and grid

4. Replace thermocouple

5. Replace control

6. Replace tip over switch

TROUBLESHOOTING

WARNING: Never attempt to service heater while it is connected

to propane supply, operating or hot. Severe burns can occur.

Advertising