Cleaning and maintenance, Operating instructions – Desa 35-R User Manual

Page 6

Advertising
background image

www.desatech.com

117296-01A

6

LIGHTING HEATER

1. Before attempting to light the heater check

for gas leaks. Turn on the gas supply to the

appliance and check all fittings and connec-

tions for gas leaks using a mild soap and water

solution. NEVER use a match to check for gas

leaks. Should a gas leak occur, shut off the gas

supply to the appliance immediately. Correct

all leaks at once.

2. Use only the fuel intended for this appliance.

Check the appliance rating plate for the correct

fuel information.

3. Turn on the main gas supply.
4. Press and hold button on control valve.
5. Press button on piezo ignitor 6 to 8 times.

Burner should light.

Note:

In cases where long runs of gas supply lines

have been installed ahead of the appliance, it may

be necessary to bleed trapped air out of supply lines

before lighting pilot. New installations generally

require bleed of supply lines. Wait a minimum of

five minutes after bleeding supply lines before

attempting to light heater.
IMPORTANT:

DO NOT attempt to adjust the

main burner input using the main gas supply valve.

This may cause the pilot and thermocouple to shut

down the burner.

SHUTTING OFF HEATER

1. Close propane gas supply cylinder valve.
2. Observe the burner until flame is extin-

guished.

3. Listen for closure of the safety valve.
IMPORTANT:

DO NOT reopen the propane gas

supply cylinder valve before the safety valve

closes.

CLEANING AND

MAINTENANCE

WARNING: Never attempt

to service heater while it is

connected to propane supply,

operating or hot. Severe burns

can occur.

1. Turn heater off and let cool at least 20 minutes

before cleaning.

2. Keep heater clean. Clean heater annually or as

needed to remove dust and debris. If heater is

dirty or dusty, clean heater with a damp cloth.

Use household cleaners on difficult spots.

3. Inspect heater before each use. Check connec-

tions for leaks. Apply mixture of liquid soap

and water to connections. Bubbles forming

show a leak. Correct all leaks at once.

4. Clean inside of heater using compressed

air. Blow air back and forth along the entire

burner face until all dust has been dislodged

from surface of reverberator and screen. Blow

air through venturi from the control end of

heater.

5. Inspect hose/regulator assembly before each

use. If hose is highly worn or cut, replace.

6. Have heater inspected yearly by a qualified

service agency.

OPERATING

INSTRUCTIONS

Continued

To Match Light the Pilot
Hold a lit match to the burner face while pressing

and holding the control valve button. After the

burner ignites, keep button pressed for one (1)

minute or until the burner stays lit after releasing

button. DO NOT light gas at the burner orifice. DO

NOT face heater when attempting to light. Always

stand to the side of the unit when lighting.

CAUTION: When lighting

burner with a match or taper,

light at bottom of screen. Not

at orifice.

Figure 2 - Heater Parts

Control
Valve Button

Piezo
Ignitor
Button

Ignitor
Electrode

Thermocouple

Burner

Advertising