Installation – Desa CDCFNRA User Manual

Page 12

Advertising
background image

www.desatech.com

116658-01A

12

15"

18"

21"

23"

2

1

/

2

"

6"

8"

10"

Note:
All vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.

INSTALLATION

Continued

Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening (see Figure 10).

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• raise the mantel to an accept-

able height

• remove the mantel

Figure 10 - Minimum Mantel Clearances

for Built-In Installation

Mantel Shelf

Side of Firebox

Figure 11 - Removing Top Louver and

Opening Bottom Louver

O
F

F

P

IL

OT

O

N

H

I

L

O

Top
Louver

Bottom Louver

OPTIONAL MANTEL INSTALLATION

Note:

Refer to instructions provided with the

mantel for assembly instructions. Refer to the

following instructions for system installation.

Refer to instructions on page 6 for hood assembly.

Blower accessory should be installed if it is being

used (see Installing Optional Blower Accessory

GA3450TA, page 13).
1. Unscrew four screws that attach top louver to

fireplace. Remove louver from fireplace and

set aside (see Figure 11).

2. Place base assembly next to wall at installation

location.

3. Place fireplace on wood base (see Figure 12,

page 13).

4. Place mantel around fireplace on base (see

Figure 12, page 13).

5. Assemble perimeter trim kit. See Assembling

Perimeter Trim, page 13.

6. Firmly snap perimeter trim kit on shoulder

screws. Shoulder screws are located on fire-

place cabinet (see Figure 12, page 13).

7. Align perimeter trim kit for flush fit around

opening.

8. Center mantel left to right on base making sure

mantel is flush against wall.

9. Use two 3" wood screws provided and attach

base of fireplace to wooden mantel base (see

Figure 12, page 13).

10. Remove perimeter trim kit and mantel. Be

careful not to damage wall or mantel.

11. Cut an access hole in base to run flexible gas

line to fireplace (see Figure 12, page 13). Make

sure to locate access hole so mantel will cover

it when installed. Note: You can secure base

to floor using wood screws. Countersink screw

heads and putty over.

Advertising