Installation – Desa CDCFNRA User Manual

Page 11

Advertising
background image

www.desatech.com

116658-01A

11

INSTALLATION

Continued

WARNING: If pre-wiring, do

not connect wiring to any electri-

cal source at this time.
Install fireplace electrical outlet

and connect wiring to outlet

before connecting to electrical

source. The fireplace electri-

cal outlet is included with the

GA3450TA blower accessory.
Only use the fireplace electri-

cal outlet supplied with the

GA3450TA blower accessory.

Note:

A qualified installer should make all electri-

cal connections.
3. Install gas piping to fireplace location. This

installation includes an approved flexible gas

line (if allowed by local codes) after the equip-

ment shutoff valve. The flexible gas line must

be the last item installed on the gas piping.

4. If you have not installed hood, follow instruc-

tions on page 6.

5. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

6. Attach flexible gas line to fireplace gas regula-

tor. See Connecting Equipment Shutoff Valve

to Heater Control, page 17.

7. Bend four nailing flanges on outer casing with

pliers (see Figure 9).

8. Attach fireplace to wall studs using nails or

wood screws through holes in nailing flange.

Figure 9 - Attaching Fireplace to Wall

Studs

Nailing
Flanges

Nails or
Wood
Screws

Wall Studs

9. Check all gas connections for leaks. See Check-

ing Gas Connections

, page 17.

10. If using optional brass trim kit, install the trim

after final finishing and/or painting of wall.

See instructions included with brass trim ac-

cessory for attaching brass trim.

IMPORTANT:

When finishing your firebox,

combustible materials such as wall board, gypsum

board, sheet rock, drywall, plywood, etc. may be

butted up next to the sides and top edge of the fire-

box. Combustible materials should never overlap

the firebox front facing.

WARNING: Do not allow any

combustible materials to overlap

the firebox front facing.

IMPORTANT:

Noncombustible materials such as

brick, tile, etc. may overlap the front facing, but

should never cover any necessary openings like

louvered slots.

WARNING: Do not allow

noncombustible materials to

cover any necessary openings

like louvered slots.

WARNING: Never modify or

cover the louvered slots on the

front of the firebox.

WARNING: Use only noncom-

bustible mortar or adhesives when

overlapping the front facing with

noncombustible facing material.

Advertising