Datalogic Scanning TC1100-1200 User Manual

Tc1100, Ccd scanner quick reference guide

Advertising
background image

CODE SELECTION

EAN/UPC disable

AA0

EAN 8/EAN 13/UPC A/UPC E enable

AA1
AA5
AA8

without ADD ON
with ADD ON
with and without ADD ON

EAN 8/EAN 13 enable

AA3
AAK
AAL
AA6

without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5

UPC A/UPC E enable

AA4
AAM
AAN
AA7

without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5

EAN 8 enable

AAG0
AAG1

check digit transmission disable
check digit transmission enable

EAN 13 enable

AAH0
AAH1

check digit transmission disable
check digit transmission enable

UPC A enable

AAI0
AAI1

check digit transmission disable
check digit transmission enable

UPC E enable

AAJ0
AAJ1

check digit transmission disable
check digit transmission enable

Code 39 disable

AB0

Code 39 Standard enable

AB11xxyy
AB12xxyy
AB13xxyy

no check digit control
check digit control and transmission
check digit control without transmission

Code 39Full ASCII enable

AB21xxyy
AB22xxyy

no check digit control
check digit control and transmission

Code 2/5 family disable

AC0

Interleaved 2/5 enable

AC11xxyy
AC12xxyy
AC13xxyy

no check digit control
check digit control and transmission
check digit control without transmission

Normal 2/5 5 bars enable

AC21xxyy
AC22xxyy
AC23xxyy

no check digit control
check digit control and transmission
check digit control without transmission

Industrial 2/5 (IATA) enable

AC31xxyy
AC32xxyy
AC33xxyy

no check digit control
check digit control and transmission
check digit control without transmission

Matrix 2/5 3 bars enable

AC41xxyy
AC42xxyy
AC43xxyy

no check digit control
check digit control and transmission
check digit control without transmission

Codabar family disable

AD0

Codabar standard enable

AD111xxyy
AD112xxyy
AD121xxyy
AD122xxyy
AD212xxyy

no start/stop character equality control - nor transmission
no start/stop character equality control but transmission
start/stop character equality control but no transmission
start/stop character equality control and transmission
ABC Codabar no start/stop character equality control but transmission

Code 128 family disable

AI0

Code 128 enable

AI11 xxyy

control without transmission of check digit

EAN 128 enable

AI21 xxyy

control without transmission of check digit

Code Length

AILxxyy

Code 93 family disable

AK0

Code 93 enable

AK1 xxyy

control without transmission of check digit

PDF417 disable

AR0

PDF417 enable

AR1

Pharmacode disable

AQ0

Pharmacode enable

AQ1xxyy
AQ2xxyy

forward code tx direction
reverse code tx direction

Overflow ratio

AQAzz

xxyy = ASCII numbers that define:
xx = min. acceptable code length

yy = max. acceptable code length

zz = overflow ratio value

The minimum code length must always be less than or equal to the maximum.

For more detailed information on the TC1100 programmability and complete parameter list, please refer to the
TC1100 Reference Manual.

N2468

821000676 (Rev. H)

TC1100

CCD Scanner
Quick Reference Guide

The TC1100 is a linear CCD Scanner for OEM applications. It is available in two different versions:

Model Description

Order

Number

TC1100-1100

CCD scanner for linear codes

939501020

TC1100-1200

CCD scanner for linear and PDF417

939501030

Technical Specifications

Power supply

5 Vdc

± 5%

Consumption 1.5

W

Interfaces

RS232, WEDGE, PEN Emulation

Max Scans/sec

270

Max resolution

0,076mm (3mils)

Readable codes:

EAN/UPC, Code 39, 2/5 family, Codabar, Code 128, EAN 128, ISBT 128, Code 93,
pharmaceutical codes, Delta IBM, Code 16K, Code 49, (Telepen, MSI/Plessey, Pharmacode
only TC1100-1100), (Codablock-A, Codablock-F Std, Codablock-F EAN, PDF417 only
TC1100-1200)

Default Configuration

Power Save

270 scans/sec, sleep disabled, standby disabled

Reading Parameters

On-Line

Code Selection

Enabled codes

(Only TC1100-1200)

• Interleaved 2 of 5: Check Digit transmitted, length: min 4, max 99

• Code EAN8, EAN13, UPCA, UPCB: without ADD ON, Check Digit transmitted, no conversions

• Code 39: length: min 1, max 99

• Code 128: Check Digit not transmitted, length: min 1, max 99

• PDF417

Data Format

Code ID disabled, Header = <STX>, Terminator = <CR> <LF>, no Field Adjustment, Code
length TX disabled, character replacement disabled, No Read Character = <CAN>

Decoding Parameters

Ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver

disabled, decoding safety = 1 read

Enabled interface

RS232, 9600, N, 8, 1, no handshaking, ACK/NAK disabled, RX timeout 100 ms, FIFO
enabled, inter-character delay disabled

Reading Diagrams

-160

-140

-120

-100

-80

-60

-40

-20

0

20

40

60

80

100

120

140

160

0

20

40

60

80

100 120

140 160 180 200 220

240 260

280 300

320

0.13 mm

(5 mils)

0.30 mm

(12 mils)

0.50 mm

(20 mils)

0.20 mm

(8 mils)

0.20 mm

mm

-90

-80

-70

-60

-50

-40

-30

-20

-

10

0

10

20

30

40

50

60

70

80

90

0

10

20

30

40

50

60

70

80

90 100 110 120 130 140 150 160 170 180

0.17 mm

(6.6 mils)

0.38 mm

(15 mils)

0.25 mm

(10 mils)

mm

Reading Diagram TC1100-1100 (code 39)

Reading Diagram TC1100-1200 (PDF417)

Advertising
This manual is related to the following products: