Ì$+cp0$-$î, Return to rs232 interface – Datalogic Scanning TC1100-1200 User Manual

Page 2

Advertising
background image

Electrical Connections

25-pin connector

1 Shield

earth

ground

2 TX

transmit

data

3 RX

receive

data

4

RTS

request to send

5

CTS

clear to send

6 nc

not

connected

7 SGND

signal

ground

8

EXT BEEPER

external beeper connection

9 VCC+

+5Vdc

10 nc

not

connected

11 OUT+
12 OUT-

See Figure 1

13 VCC+

+5Vdc

14 nc

not

connected

15 nc

not

connected

16 nc

not

connected

17 nc

not

connected

18 EXT

TRIG+

19 EXT

TRIG-

See Figure 2

20 DATAIN_WAND
21 DATAOUT

22 OUT-

23 CLKIN

24 CLKOUT

25 GND

power

ground

Led Status

ON = Power ON

POWER ON

OFF = Power OFF
ON = Good Read

(the LED will remain ON until status changes)

GOOD READ

OFF = No Read

54

[2

.13]

7.

6

[0.3

0]

30.5

[1.2

0]

31.6

[1.25]

24

[0.94]

9.5

[0.3

7]

10.4

[0.41]

70

.7

[2

.78]

68.6

[2.70]

mm
[in.]

17

.7

[0

.70]

Optical Axis

EXT TRIG+

18

19

+ 5V

TC1100

EXTERNAL TRIGGER

Signal

V

30 Vdc max.

Vext

EXT TRIG-

18

19

+ 5V

TC1100

EXTERNAL TRIGGER

30 Vdc max.

Vext

V

Signal

Ground

EXT TRIG+

EXT TRIG-

Input NPN command using external power

Input PNP command using external power


EXTERNAL TRIGGER

TC1100

Signal

18

19

+ 5V

13

25 GND

Ground

V

EXT TRIG+

EXT TRIG-

Vcc 5Vdc

EXTERNAL TRIGGER

TC1100

18

19

+ 5V

Vcc 5Vdc

13

25

GND

Ground

V

Signal

EXT TRIG+

EXT TRIG-

Input NPN command using TC1100 power

Input PNP command using TC1100 power

Figure 2 - Trigger Connections

Basic Commands for TC1100

The TC1100 default configuration can be changed by receiving commands through the RS232
Interface. The command syntax is given below with an example.

Command syntax
$+ Command(s) $- <CR> the new setting will be definitive (stored in FLASH EPROM)

Example:

Baud Rate = 19200

Serial On-Line Operating Mode

BK0

$-

CR

Carriage return character (0D Hex.)

Exit and save new configuration

AC410132

CD7

Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters

$+

Enter configuration environment

Multiple command programming sequence:

Commands:

OPERATING MODES

On-line

BK1

Serial On-line

BK0

Automatic

BK3

Automatic / Lighting System Standby

BK2

To enter in Test mode

#+DStat1<CR> (does not require $+ or $-)

To exit Test mode

#+DStat0<CR> (does not require $+ or $-)

GENERAL FEATURES

RS232 interface selection

CP0

RS232 Baud Rate

CD0

for 150 Baud up to CD8 for 38400 Baud

WEDGE AT

CP500

WEDGE Notebook

CP505

Keyboard Nationality

FJ7 Belgian
FJ4 English
FJ2 French
FJ3 German

FJ1 Italian
FJ6 Spanish
FJ5 Swedish
FJ0 USA

CCD Scan Rate

BT0 67

scans/sec

BT1 135

scans/sec

BT2 270

scans/sec

Puzzle Solver

AU1 enable

AU0 disable

Ink Spread

AX1 enable

AX0 disable

Decoding safety

ED0 1

read

ED1 2

reads

ED2 3

reads

ED3 4

reads

To restore the default configuration

$+$*<CR> (does not require $-)

To get configuration from the scanner

$+$&<CR> (does not require $-)

Return to RS232 Interface

Ì$+CP0$-$Î

For WEDGE Users

USER INTERFACE

Vext 40 Vdc max

OUT +

11

12

OUT -

TC1100

Figure 1 - Output Connection (Good Read). Example NPN

Physical Dimensions

Width

70.7 mm

2.78 inches

Length

68.6 mm

2.70 inches

Height

30.5 mm

1.20 inches

Advertising