ADLINK PCM-9112+ User Manual

Page 4

Advertising
background image

4

2.5.1

Analog input mode configuration

The analog input channels on the PCM-9112+ DAQ module can be configured as 16 single-ended
or 8 differential inputs. Jumpers JP1 and JP4 control the analog input configuration. The setting of
JP1 and JP4 are specified below:

Analog Input Setting

Single-ended

input (Default)

Differential input

Table 3: Analog input mode configurations

2.5.2

Clock Source Setting

The programmable 8254-interval timer is used in the PCM-9112+. It provides 3 independent 16-bit
programmable down counters. Input of counter 2 is connected to an accurate 2MHz oscillator used
as the internal pacer. Input of counter 1 is cascaded from the output of counter 2. Channel 0 is
free for user applications. There are two selections for the clock source of channel 0: the internal
2MHz clock or an external clock signal. The setting for clock signal is shown in the following table.

Clock source setting

Internal Clock

Source: 2MHz

(default)

External Clock

Source

Table 4: Clock source setting