Jp3/jp7, Jp1/jp2 jp5/jp9 – ADLINK ACL-6128A User Manual
Page 22
Advertising
14
• Installation
ACL-6128 settings (Note: this table is for the older ACL-6128 ONLY. The
ACL-6128 PCB has misprints. Please refer to the chart below for correct
jumper placement.)
Jumper
Output Range
JP3 for CH1
JP7 for CH2
JP1 & JP5 for CH1
JP2 & JP9 for CH2
0 to +5V
Unipolar
(Default)
JP3/JP7
-10
-5
JP1/JP2 JP5/JP9
UP
BP
UP
BP
0V to +10V
Unipolar
JP3/JP7
-10
-5
JP1/JP2 JP5/JP9
UP
BP
UP
BP
-5V to +5V
Bipolar
JP3/JP7
-10
-5
JP1/JP2 JP5/JP9
UP
BP
UP
BP
-10V to +10V
Bipolar
JP3/JP7
-10
-5
JP1/JP2 JP5/JP9
UP
BP
UP
BP
Figure 2.6 Output Range Summary
Advertising