Operation Theory

45

Figure 4-8: DIREQ as input data strobe (Falling Edge Active)

Note:

From the timing diagram of external clock mode, the maxi-

mum frequency can be up to 40MHz. However, users should

note that when the sampling frequency of digital input is

higher than the PCI bus bandwidth (33Mhz), or the band-

width of chipset (30Mhz typically) from PCI bus to system

memory. Users should check the overrun status when the

DMA block size is larger than 16K samples. If overrun al-

ways happens, users should reduce the DMA block size or

slow down the sampling frequency. For example, the DMA

block size should be smaller than 64K when the external

clock is 40Mhz in the DOS Operation

Digital Input DMA in Handshaking Mode

For digital input, through DI-REQ input signal and DI-ACK output
signal, the digital input can have simple handshaking data trans-