5 star trigger – ADLINK PXI-7921 User Manual

Page 31

Advertising
background image

Operation Theorem

25

Figure 13: Available signal sources for Trigger Bus[7..0]

4.5 Star Trigger

The PXI specification defined 13 matched trigger lines to connect to the first 13
PXI peripheral slots on a PXI backplane. Users can route various trigger signal
to synchronize multiple PXI instruments and achieve tight timing control.

On ADLINK Switch Modules, the star trigger driver is disconnected from the PXI
backplane before users’ configuration. The maximum skew between each star
trigger line is controlled to within 1ns.

Note the reverse input voltage protection range is -0.5V to +5.5V. When the
local bus is used on peripheral modules, make sure that the voltage level is
compatible with ADLINK Switch Module.

Figure 10 illustrates the available signal destinations for Star Trigger. Signal
names in the solid-line boxes represent the external (physical) signal on
connectors, while signals in the dotted-line boxes represent the switch module’s
internal signal.

Trigger Bus[7..0]

WDT Overflow

SHDNn

Software Trigger

Star Trigger In

Trigger In Signal

Scanner Adv. Signal

AUX [3…2]