2 applications, 3 specifications – ADLINK PXI-7921 User Manual

Page 8

Advertising
background image

2

• Introduction

1.2 Applications

•

Industrial ON/OFF control

•

External high power relay driving and signal switching

• Laboratory

automation

• Industrial

automation

•

Switch contact status sensing

•

Limit switch monitoring

•

Cooperating with other modules such as A/D and D/A peripherals to
implement a data acquisition and control system

1.3 Specifications


Relay Output

•

Number of channels: 24

•

Relay type: DPDT (2 Form C), non-latching

• Switching

capacity:

•

Max. switching current: 2A

•

Max. switching voltage: 220V

DC

, 125V

AC

•

Max. switching power: 50VA, 60W

♦ Max. carrying current: 2A

•

Failure rate: 10µA

•

Contact resistance: 100mΩ max.

•

Relay set/reset time

•

Operate time: 4ms max.

•

Release time: 4ms max.

•

Bounce time: 1ms max.

• Expected

life:

•

Mechanical life: 10

8

operations min.

•

Electrical life: 5x10

5

operations min. (1A @ 30V

AC

, resistive load)

•

Data transfer: Programmed I/O

Auxiliary Digital I/O

•

Numbers of channel: 3 inputs/outputs

•

Compatibility: 3.3 V/TTL (5V tolerant)

•

Data transfers: programmed I/O

Handshaking Signals

• Programmable

polarity

•

Logic level: 3.3 V/TTL (5V tolerant)

•

Trigger In source: TRG_IN, PXI trigger bus, PXI star trigger in

•

Scanner Advanced destination: S_ADV, PXI trigger bus, PXI star
trigger out

Advertising