42

• Expansion/Isolation Box User Guide

The pin definition for RS-422/485 DB25 male connector.

Pin No.

RS-422/485 Mode Signal Name

2

TXD+ (Out)

3

RXD+ (In)

4

RTS+ (Out)

5

CTS+ (In)

7

GND

13

RTS- (Out)

14

TXD- (Out)

16

RXD- (In)

19

CTS- (In)

RS-485 mode may let pin 2 and pin 3, pin 14 and pin 16 short together to
connect with other device.

We have 120-ohm terminator resistor built in each input signal pair. In
RS-485 mode, you may need to remove this terminator resistor.

Mode setting for C584XB/C588XB

DIP Switch Bit 1,3,5,7 DIP Switch Bit 2,4,6,8

Interface Mode

ON

ON

RS-232

ON

OFF

RS-232

OFF

ON

RS-422

OFF

OFF

RS-485