Input characteristics, Output characteristics – ADLINK cPCIS-2500 Series User Manual

Page 32

Advertising
background image

26

Power Supply Unit

Input Characteristics

Input Voltage: Typ. 90-264VAC

Power Factor Correction: Meets Harmonic Correction IEC1000-3-2.
Power Factor typ. 0.95-0.97

Input Connector: Positronic 47-pin PCIH47M400A1

Input Frequency: 47-63Hz

Inrush Current: Less than 30A @ 230VAC

Input Current: 2.8A @115VAC / 1.4A @230VAC

Dielectric Withstand: Meets IEC950 regulation

EMI: Meets EN55022 / FCC Class A

Hold-up Time: 5mS after power fail signal

Remote ON/OFF: Available at [INH#] & [EN#] pins

Power Fail Signal: Available at [FAL#] pin

Status LED: <Green> means valid input voltage; <Amber> means a
critical fault.

Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin

Power OK: Installed at all outputs

Leakage Current: Typ. 0.5mA

Output Characteristics

Output Current (A)

Output

Voltage

MIN.

MAX.

TYP.

PEAK.

5V

MAIN +VO1

@ ★ # ≡ ☉

2.0 33.0 25.0

3.3V

AUX. +VO2

▲ @ ★ # ≡ ☉

0 33 18 –

12V

AUX. +VO3

# ☉ ★ @

0 5.5 5.5 6

-12V

AUX. –VO4

● ☉ ★ ■ =

0 1 0.5

1.5

Advertising