Power Supply Unit

27

Symbol: "★" OVP built-in; "@" Adjustable; "#" Remote sensing;

"≡" 3rd-wire Load Sharing; "=" Droop Current Sharing;
"☉" Installed with Or-ing diode; "▲" Magnetic Amplifier;
"●" Installed with Post-regulator; "■" Common Choke.


Remarks: Peak load sustainable for less than 60sec. with duty cycle <10%.

Max. load is the continuous operating load of each rail. Max. load
of each rail cannot be drawn from all outputs at the same time.

Over Load Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.

Over Current Protection: Installed at each rail

Output Wattage: Typ. 250W continuous.

Output Connector: Positronic 47-pin PCIH47M400A1.

Line Regulation: Typ. 0.1%.

Load Regulation: Typ. ±1–2%.

Noise & Ripple: Typ. 1% peak to peak or 50mV, whichever is
greater.

OVP: Built-in at all outputs.

Adjustability: Available at VO1, 2 & 3.

Output Trim: Electrical trim available at VO1/VO2 [ADJ #].

Remote Sensing: Available at VO1, VO2 & VO3.

• Hot-Swap:

Available.

N+1 Redundancy: Installed with internal OR-ing diodes at all outputs
for N+1 redundancy operation.

• Current

Sharing:

Third-wire

current sharing at VO1,2 &3.

Power OK Signal: Available for all output.

Over Current Protection: Installed at each rail.

Overload Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.