2 auxiliary power cord, Auxiliary power cord – ADLINK cPCI-R6700 Series User Manual
Page 40
Advertising
![background image](/manuals/733557/40/background.png)
28
Getting Started
4.2
Auxiliary Power Cord
If required, install the Auxiliary Power Cord included in the pack-
age.
1. Locate the Auxiliary Power Cord (20 cm) in the package.
2. Connect the 6-pin power connector to the cPCI-R6700
RTM (CN8).
3. After the RTM is installed in the chassis (see “Installing
the cPCI-R6700” on page 29 below), connect either the
male or female 4-pin Molex connector to the power supply.
CAUTION:
Additional power supply must be supplied to the RTM using an
auxiliary power cord when the cPCI-R6700 is used with a CPU
blade that consumes over 50W of power or under extended
temperature conditions (>60°C).
To CN8 onboard
connector
To ATX
power supply