Environmental specifications, Table 3, Table 4 – ADLINK MilSystem 735 User Manual

Page 8: Environmental requirements

Advertising
background image

MilSystem Setup

4

User’s Guide

MilSystem

Table 3

lists the current draw values of the MilSystem with the LittleBoard 800.

Operating configurations:

In-rush operating configuration includes one LittleBoard 800, 1GB DDR RAM, AMI BIOS, AC/DC
external digital power supply, DC/DC internal power module, CRT monitor, HDD, keyboard and

mouse.

Idle operating configuration includes the same items as the In-rush configuration.

BIT (Burn-In-Test) operating configuration includes the same items as the Idle configuration as well as
four serial loop backs, one parallel port with loop back, two Ethernet connections, four external USB
flash drives, and one Compact Flash card.

Environmental Specifications

Table 4

provides the most efficient operating and storage condition ranges required for this system with the

LittleBoard 735, LittleBoard 800, and COM 840.

Table 3. System Power Requirements (LittleBoard 800, 1.4 GHz Pentium M CPU)

Input Type

In-rush Current
(@ 170.88W Power)

Typical Idle Current
(@ 9.54W Power)

Typical BIT Current
(@ 13.18W Power)

+14VDC

12.21A

0.68A

0.94A

+16VDC

10.68A

0.60A

0.82A

+18VDC

9.49A

0.53A

0.73A

+20VDC

8.54A

0.48A

0.66A

+22VDC

7.77A

0.43A

0.60A

+24VDC

7.12A

0.40A

0.55A

+26VDC

6.57A

0.37A

0.51A

+28VDC

6.10A

0.34A

0.47A

+30VDC

5.70A

0.32A

0.44A

+32VDC

5.34A

0.30A

0.41A

NOTE

Extended temperature range available only on extended temperature tested
(ETT) systems.

Table 4. Environmental Requirements

Temperature

Humidity

Operating

Storage

Extended

Operating

Non-operating

-20

° to +65°C

(-4

° to +149°F)

–55° to +85°C
(–67° to +185°F)

–40° to +75°C
(–40° to +167°F)

5% to 90%
relative humidity,
non-condensing

5% to 95%
relative humidity,
non-condensing

Advertising