HORIZONTAL INSTALLATION

EXHAUST VENT TERMINATION SHALL BE AS FOLLOWS:

A MINIMUM OF 4 FEET/122Omm BELOW, BESIDE AND 1 FOOT ABOVE ANY DOOR OR WINDOW THAT OPENS,
OR ANY OPENING INTO A BUILDING.

A MINIMUM OF 2 FEET/610mm FROM ANY ADJACENT BUILDING OR OVERHANG.

A MINIMUM OF 7 FEET/2130mm ABOVE GRADE, WHEN LOCATED ADJACENT TO PUBLIC WALKWAYS.

A MINIMUM OF 2 FEET/610mm ABOVE GRASS, PLANTS OR OTHER COMBUSTIBLES.


Note: The pipe lengths shown are for reference only.
Your actual pipe length requirements may differ.

SINGLE WALL PIPE SHALL NOT BE
USED FOR ANY INSTALLATION.


HORIZONTAL INSTALLATION SHALL
BE A MAXIMUM OF 5’ FEET.




















WARNING:
Vent surfaces can become hot enough to cause burns
if touched. Non-combustible shielding may be required.

PLEASE FOLLOW THE PIPE MANUFACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES FOR
THE CLEARANCES TO COMBUSIBLES REQUIRED FOR INSTALLATION OF THE VENT PIPE BEING USED.


MINIMUM 6"

(152mm)

CLEARANCE

STOVE ADAPTER

12”

(304 mm)

Wall Thimble