PROBLEM

CAUSES

SOLUTIONS


? Fire goes out or stove shuts down
automatically.

♦ Hopper is empty.

♦ Fuel is not feeding.

♦ High limit temperature switch has

tripped.

♦ Vacuum pressure switch has

tripped.

♦ Poor quality or wet fuel.

♦ Combustion air too high.

♦ Fuel feed rate is too low.

9 Refill hopper.
9 See “Pellets will not feed” below.
9 Allow stove to cool for 1 hour and

relight after re-setting the high
temperature thermodisk. If this
problem persists, particularly at
lower burn rates, then the high limit
snap switch should be replaced by
your authorized Magnum reseller.


9 Correct cause of pressure switch

tripping. Have an authorized tech
service unit. Install outside air.


9 Replace fuel with proper fuel.
9 Adjust the damper to reduce

combustion airflow.

9 Have your Magnum reseller adjust

the fuel control.


? Fuel will not feed.

♦ Hopper is empty.

♦ Auger, circuit board, high limit

switch tripped

♦ Foreign object caught in auger

♦ Fuel is dirty or wet

♦ Auger, circuit board, pressure

switch or relay.

9 Check contents of the hopper. Add

fuel if necessary.

9 Check all operation, fuses, re-set

manual high limit thermodisk

9 Clean out auger system
9 Have your Magnum reseller

diagnose the problem and replace
the parts.


? Stove runs for 15 minutes and then
shuts down.

Exhaust gas is not up to
temperature.

♦ Low limit snap switch not operating

correctly; may be defective.

♦ Wires to either the low limit snap

switch (mounted on the side of the
firebox) are loose or disconnected.

9 Relight the stove.
9 Have your Magnum reseller replace

the low limit switch.

9 Contact your Magnum reseller for

service.

? Blower will not shut off after the fuel
has been switched off and the stove has
cooled down.

♦ Low limit snap switch has failed in

the closed position.

♦ Unit has not cooled down yet.

9 Have your Magnum reseller replace

the low limit snap switch.

9 It can take up to 1 hour for the unit

to cool down enough for the blower

to shut off. If it takes longer than 2
hours for the blower to shut off or if
it fails to shut off contact your local
Magnum service technician.