PROBLEM

CAUSES

SOLUTIONS

? Blower will not operate.

♦ No power to stove.

♦ No power to control board.

♦ Blower has overheated due to dirt

on blades or in motor

♦ Blower is defective

9 Check to see that the stove is

plugged into the wall outlet.

9 Check to see if your circuit breaker

has “tripped”.

9 Check wire connection between the

high limit snap switch and the
terminal block.

9

Clean blades and motor, have a
Magnum tech replace blower.

? Soot or fly ash in the house.

♦ Cleaning the window, particularly

when the stove is operating.

♦ Leakage on the joints between the

combustion fan, exhaust pipe and
“PL” vent. This will be evidenced
by dust on the impeller of the
convection fan and in the heat
exchanger tubes.

♦ Using a conventional vacuum for

cleaning. Ash will bypass and enter
the room.

♦ Negative pressure in home sucking

ash/soot out of venting and unit

♦ Fireplace insert installation: If the

existing fireplace opening was not
thoroughly cleaned and painted
before the insert was installed, then
the convection fan may be picking
up the fireplace dust, soot or ash
and blowing it into the house.

9 Clean the glass when the unit is not

running

9 Seal any leaks in the exhaust

system with RTV high temperature
silicone sealer.

9 Use approved ash Vacumm

9 Correct negative pressure situation

9 Pull the insert away from the

fireplace opening. Thoroughly
clean the opening and paint the
inside of the opening with latex or
an inexpensive spray paint to hold
the finer particles of dust.


? Buildup of soot on glass, venting and
heat exchangers

♦ Dirty fuel

♦ Inadequate air supply

♦ Negative pressure in home

♦ Air wash plugged or out of

adjustment

9 Make sure you have clean fuel
9 Pull manual draft control out

slightly to make sure that there is
app. ½ inch of fuel in firepot

9 Install outside air to unit and make

sure that the home has adequate
make-up air. (suggested 6” make-
up air into basement)

9 Clean air-wash bracket located on

bottom of glass door

CAUTION: When performing any internal electrical maintenance

• Moving parts inside of the cabinet may cause injury. Do not operate unit with panels removed or open.

• HOT parts. Do not operate the unit with panel open.

• Risk of electrical shock. Disconnect power before servicing unit.

• In the event of component failure, replace with original factory equipment.

IMPORTANT: Electrical work must be performed by an authorized technician.