Clearances – American Energy Systems MagnuM Baby Countryside User Manual

Page 9

Advertising
background image

9

CLEARANCES


CONVENTIONAL CLEARANCES


A…SIDEWALL

9 In. (229 mm)

B…BACK WALL

3 In. (75 mm)……(VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”

CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).

C…CORNER WALL

3 In (75 mm)…….(VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”

CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).

D…VENT PIPE TO WALL 3 In (75 mm)……..(MAINTAIN 3” INCH CLEARANCE FOR ALL INSTALLATIONS)

E…FLOOR PROTECTION FRONT 6 In (150 mm)
F…FLOOR PROTECTION SIDES

9 In (229 mm)

Floor protection must be 3/8” inch minimum thickness non-combustible material or equivalent extending beneath heater and to the front/side/rear as indicated.

CHIMNEY AND CONNECTOR: 3” LISTED PELLET VENT ONLY

NOTE: REGARDLESS OF STOVE CLEARANCE, VENT PIPE MUST ALWAYS HAVE A 3” INCH CLEARANCE.


ALCOVE CLEARANCES

MIN. ALCOVE WIDTH 38 In. (965 mm)
MIN. ALCOVE HEIGHT 47 In. (1194 mm)
MAX. ALCOVE DEPTH 36 In. (914 mm)
MAX. ALCOVE DEPTH 36 In. (914 mm)

WARNING: THE MINIMUM CLEARANCES LISTED ABOVE ARE BASED ON 3” INCH PL LISTED PELLET
VENT PIPE. IF YOUR APPIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT. PLEASE
FOLLOW THE PIPE MANUFACTURERS INSTRUCTIONS AND LOCAL BUILDING CODES FOR THE
CLEARANCE TO COMBUSTIBLES REQUIRED FOR THE INSTALLATION OF THE VENT PIPE BEING USED.