Denon AVR-3808 User Manual
Page 17
- 17 -
Z2 COMMAND : "*" parameter uses two ASCII characters. (see page4 J) section)
COMMAND PARAMETER
function example
Z2
PHONO
MULTI ZONE-2 mode set , and select source at AVR-3808
Z2PHONO<CR>
|
---The name of PARAMETER is
|
IPOD
the same as that of the time of SI COMMAND.
Z2IPOD<CR>
SOURCE
MULTI ZONE-2 mode cancel at AVR-3808
Z2SOURCE<CR>
UP
MULTI ZONE-2 VOLUME UP/DOWN , direct change to **dB
Z2UP<CR>
DOWN
at
AVR-3808
Z2DOWN<CR>
**
**:10 to 99 by ASCII , 80=0dB, 99=---(MIN)
Z280<CR>
ON
MULTI ZONE-2 ON/OFF change at AVR-3808
Z2ON<CR>
OFF
Z2OFF<CR>
?
Return
Z2
Status
Z2?<CR>
Z2MU
ON
ZONE2 OUTPUT MUTE ON/OFF change
Z2MUON<CR>
OFF
Z2MUOFF<CR>
?
Return Z2MU Status
Z2MU?<CR>
Z2CS ST
ZONE2 Channel setting
Z2CSST
MONO
Z2CSMONO
?
Return Z2CS Status
Z2CS?
Z2CV FL
UP
ZONE2 CHANNEL VOLUME UP/DOWN , direct change to **dB
Z2CVFL UP<CR>
FL
DOWN ---FRONT Lch
Z2CVFL DOWN<CR>
FL
** **:38 to 62 by ASCII , 50=0dB
Z2CVFL 50<CR>
FR
UP ZONE2 CHANNEL VOLUME UP/DOWN , direct change to **dB
Z2CVFR UP<CR>
FR
DOWN ---FRONT Rch
Z2CVFR DOWN<CR>
FR
** **:38 to 62 by ASCII , 50=0dB
Z2CVFR 50<CR>
?
Return Z2CV Status
Z2CV?<CR>
Z2HPF ON
ZONE2 HPF ON/OFF
Z2HPFON<CR>
OFF
Z2HPFOFF<CR>
?
Return Z2HPF Status
Z2HPF?<CR>