Denon AVR-3808 User Manual

Page 6

Advertising
background image

- 6 -

Protocol specification
The following three data forms are defined.

COMMAND :

The message sent to a system(AVR) from a controller(Touch Panel etc.)

A command to a system is given from a controller.

EVENT :

The message sent to a controller (Touch Panel etc.) from a system (AVR)

The result is sent, when a system is operated directly and a state changes.

*The

form

of

EVENT presupposes that it is the same as that of COMMAND.

**Refer to the following table for the contents of COMMAND and EVENT.

RESPONSE :

The message sent to a controller (Touch Panel etc.) from a system (AVR)

if the ‘request command’ (COMMAND+?+CR(0x0D)) has came from a controller.

The

RESPONSE should be sent within 200ms of receiving the COMMAND.

*The

form

of

RESPONSE presupposes that it is the same as that of EVENT.

Basic specification

: The command by ASCII CODE, parameter expression

*ASCII CODE which can be used is from 0x20 to 0x7F: the alphabet and the number of 0-9, and space (0x20), some signs,

AND

carriage return (0x0D) --- It is used only as a pause sign.

Command structure

: COMMAND + PARAMETER + CR (0x0D)

COMMAND: ASCII CODE of 2 characters

Ex.

SI : Select Input source

MS

:

surround

Mode

Setting

MV

:

Master

Volume

setting

PW

:

system

PoWer

setting

PARAMETER : ASCII CODE ( up to 25 characters)

ex.

DVD : function name

SUPER STADIUM : surround mode name

*Special Parameter--- ? : for request command

Advertising
This manual is related to the following products: