Multi-Appliance Slimline Control

Bonaire Control Systems

Page 21

Ducted Evaporative Air Conditioning

M

OTOR AND

F

AN

Check that the fan spins freely and that there is no build up on the blades.

E

LECTRICAL

No general maintenance is required to the electrical system.

If the supply cord is damaged, it must be replaced by a special cord or assembly available from the
manufacturer or it’s service agent.

A Qualified Electrician should only carry out electrical connections and maintenance.

B

LEED

O

FF

The bleed rate should be checked to ensure it is adequate and that there is no build up of mineral deposits
in or on your air conditioner. White deposits indicate high mineral content and the Bleed Rate should be
increased. If it is at maximum and the deposits are still forming, then more regular maintenance is
required.

P

UMP

Check the pump spins freely and that the strainer is clean.

W

ATER

D

ISTRIBUTION

Check the water distribution system for blockage. Check the delivery tube for kinks or holes. Check that
the clamps are secure and in place.

N

O

S

EASONAL

M

AINTENANCE

Your unit has been supplied with an Aquamiser. As long as the Aquamiser has been fitted, there is no
need for regular checking of the system during the operating (summer) period. This however does not
remove the responsibility of the customer to have the unit service on an annual basis to check the unit
function and to ensure the unit is clean and free from any mineral deposit build up.