SLIMLINE CONTROLLER CONNECTIONS

There are two types of Inputs/Outputs connections on Slimline Controller.

1.

Digital Communications

2.

R & W Connections

Digital Communications

Digital Communication is connected to the Slimline Controller by a 4 wire cable. The Slimline Controller will
communicate with other Climate Technology products in accordance with the control system specification.

R & W Connection

This connection provides a 2 wire screw terminal for power(R) and the Heat output (W) connection. The
Slimline Controller will obtain power from these connections.

IMPORTANT: These connections are only to be used if connecting to a Heater in two wire mode. This
connection must not be used if the digital communications are connected.

NOTE: If the Slimline Controller is being used to operate both a heater and a cooler, then only digital
communication should be used.