Controls - 35
Right Control Console
5.
Shuttle home status
light
If shuttle is retracted, light
should be on.
If shuttle is extended, light
should be off.
6.
Operator presence light
If seat switch is engaged, light
should be on.
If seat switch is not engaged,
light should be off.
7.
Control cycle light
(green)
If nothing is being controlled,
light should be off.
If system is waiting for an
action before starting cycle,
light should flash on and off.
If something is being
controlled, light should be on.
If control cycle is interrupted,
light should flash twice
quickly.
8.
Remote display
Displays information from the
tracker at the drilling unit
operator’s station.
See tracking system operator’s
manual for information.
9.
Rotation pressure
gauge
Displays hydraulic fluid
pressure to rotation motor
when spindle is turned
clockwise.
Item
Description
Notes