It is important that vents and vent

connectors be installed only in

accordance with simpson dura-vent

installation instructions. A major cause

of fire related problems with vents and

vent connectors is the failure to install

with required clearances (air spaces) to

combustible materials. Read through all

of these instructions before beginning

your installation. Failure to install

the connector as described in these

instructions will void the manufacturers

warranty and may have an effect on your

homeowners insurance and UL listing.

INTRODUCTION

DuraConnect & DuraConnect II are

flexible aluminum connector systems,

with built-in twist-lock fittings for fast,

easy professional installations. No more

cutting, crimping, fitting, or fastening

with screws. Adjustable in length, simply

twist-lock, bend, and connect for an 80%

labor savings!

As safe as it is easy to install,

DuraConnect is the first and ONLY single

wall connector tested and listed by

Underwriter's Laboratories. DuraConnect

& DuraConnect II are UL listed for 1

inch clearance to combustibles, and

are flexible enough to insure greater

earthquake safety.

DuraConnect & DuraConnect II are

engineered venting systems, developed

using the Battelle Laboratories Vent

II Computer Program, plus extensive

laboratory and field testing. The inside

diameter of DuraConnect corrugated

flex system has been oversized 1/4 inch

to equalize flow resistance to that of

smooth wall pipe. By eliminating the use

of elbows, DuraConnect & DuraConnect

II systems further reduce flow resistance.

Due to the high thermal conductivity of

aluminum, DuraConnect & DuraConnect

II systems heat up rapidly. This reduces

condensate "wet time" by up to 50% - a

significant factor in vent corrosion.

DuraConnect & DuraConnect II are

designed to combat condensate

corrosion, a common problem

with galvanized steel connectors.

DuraConnect (single wall) and

DuraConnect II (double wall) are

constructed of aluminum flex - providing

the same metallurgical protection and

proven performance as the inner liner

material in Type B Gas Vent.

APPLICATIONS

The DuraConnect & DuraConnect II

flexible connector systems may be

used as a connector between the gas

appliance outlet and a double-wall

Type B gas vent or masonry chimney.

DuraConnect & DuraConnect II flexible

connectors may be used with both

draft hood equipped appliances and

fan-assisted Category I appliances. Gas

appliances may be connected as a single

appliance, or in multiples, provided the

connectors and the vents are properly

sized. DuraConnect & DuraConnect II

systems may be installed in conditioned

and unconditioned spaces. Refer to

National Fuel Gas Code for restrictions

on location and operation of equipment

and vents. DuraConnect & DuraConnect

II systems can not be installed in attic

spaces. DuraConnect & DuraConnect

II systems may not be used to pass

through walls, ceilings, floors, or other

combustible materials.