TECHNICAL REPORT

UL listing:

DuraConnect is the first and only

single wall vent connector for gas

appliances that has been tested and

listed by Underwriters Laboratories.

The DuraConnect & DuraConnect II

flexible connector pipe and fittings are

tested and listed under the UL category

of "Chimney and Vent Connectors and

Accessories." (UL File # MH14089). UL

mechanical test requirements include:

1. Torsional load testing.

2. Ceiling support and wall support load

test.

3. Load testing of fitting attachment of

flexible connectors.

4. Load testing of aluminum flexible

connectors.

5. Flexibility and cross-sectional area

tests on flexible connectors.

6. Puncture tests.

UL temperature test requirements

include:

1. Test Procedure: The flue gas

generator shall be fired per UL test

procedure #441 (470 degrees F).

The tests are to be continued until

equilibrium temperatures are reached

on nearby combustible materials. (four

hours).

2. Test Configurations: The vent

connector system is tested in both

a horizontal configuration (one inch

clearance to walls and ceiling), and a

vertical configuration (corner test at one

inch clearance to both walls). To simulate

a close clearance condition, the vent

connector was positioned at several

locations 1/4 inch from combustible

walls and ceilings for the duration of the

tests.

3. Test Requirements: Temperature

rise on combustible materials may not

exceed UL specified limits.

NATIONAL CODES

DuraConnect meets all requirements

for single wall pipe connectors of the

National Fuel Gas Code, ANSI Z223.1,

and as specified under NFPA 54, section

7.7, "Single Wall Metal Pipe", and is

in compliance with minimum wall

thickness requirements for single wall

aluminum vent connectors, section

7.10.2b. DuraConnect & DuraConnect II

meet the requirements of NFPA 211 as

specified under Chapter 5 "Chimney and

Vent Connectors", Section 5-2.1.

DuraConnect also meets the

requirements for single wall vent

connectors, of the Uniform Mechanical

Code. UL test procedures verify that

DuraConnect & DuraConnect II materials,

(which are identical to the liner thickness

of Type B Gas Vent) are "capable of

withstanding the flue gas temperatures

produced by the appliance." (Section C.)

DuraConnect & DuraConnect II are UL

listed at 1 inch clearance to combustible

materials and are in compliance with the

intent of the Uniform Mechanical Code

to limit the temperature rise in nearby

combustibles as per UL Standard #441.

DuraConnect & DuraConnect II meet the

requirements and intent of the National,

Standard, and Uniform Mechanical

Codes. The DuraConnect flexible

connector system has been approved by

SBCCI, BOCA and ICBO.