Separate good pair – EXFO MaxTester 635 User Manual
Page 223
RFL
Copper and VDSL2/ADSL2+ Multi-play Test Set
215
Separate Good Pair
Fault Status displays the status of the RFL test.
Test Status displays the current state of measurement or an error 
message.
Separate Good Pair
The RFL Separate Good Pair or 4-wire test allows you 
to determine the distance to a short, ground, or 
battery cross on a faulty cable conductor using two 
separate good cable conductors.
Connect a strap from the faulted wire to both 
conductors of the good pair.
The connection diagram shows you how to 
connect the cables to the unit.
When FED is Enabled on the FED Setup page, the 
Confirmation window pops up displaying how to 
connect your cables at the beginning of the test. 
The FED allows you to remotely place a strap (to 
short together) the T1/T/R (A1/A/B) at the far end 
for 4-wire RFL.
The Confirmation diagram uses graphic and 
textual components.
Proceed button closes the hookup diagram prompt and starts the 
test.
Cancel button closes the hookup diagram prompt only.
Note: Unlike 2-wire RFL, G/E on the FED is not grounded (on the FED side).