Ping test setup – EXFO MaxTester 635 User Manual
Page 275

Setting Up DSL/IP Tests
Copper and VDSL2/ADSL2+ Multi-play Test Set
267
Test Setup
Ping Test Setup
The Test Setup tab is available only if Access Mode is
not Sync Only.
Address Format is URL, IP Address, or Gateway.
URL/IP Address lists either the URL or IP Address
where the unit pings.
Packet Size is a value from 32 through 1200 of the
number of bytes sent in one packet. The default
value is 32.
Total Pings is the total number of Ping packets to
send out from1 through 99. The default value is 3.
Timeout is the time in seconds from 1 through 10,
that the unit will wait for a response back from the destination device.
To configure test setup values:
1. Press the up/down arrow keys to select the desired parameter.
2. Press the left/right arrow keys to view and select the options.
OR
3. Press
on a value to open a list box of options or the alphanumeric
editor screen and use the navigation keys to scroll through.
4. Press
to confirm the value.
5. If you make any changes to the parameter values, press the on-screen
function keys to save or cancel your input.