EXFO IQS-600 Integrated Qualification System User Manual

Page 189

Advertising
background image

Using IQS Products in an Automated Test Environment

Integrated Qualification System

181

Standard Status Data Structure

The following table presents a summary of the possible operations on STB
and SRE registers.

The diagram displayed on the next page is a useful aid in understanding
the general commands and how a service request (SRQ) is generated.

Using a service request, a device notifies the controller that an event
requiring special attention occurred. The controller will then find which
device generated a SRQ (its RQS bit is set) and the causes of it.

Register

Read

Write

Clear

STB

Use *STB?.

Use serial poll (GPIB

bus sequence that

allows retrieval of the

value without

interrupting the current

process).

Impossible to write;

the register content is

only modified when

the Event registers or

Queues are modified.

Use *CLS before

sending a query (to

clear the Event registers

and Queues and by the

same token clear the

STB register).

SRE

Use *SRE?.

Use *SRE with a value

equal to 0 to disable

the register or with a

value equal to 1 to

enable it.

Use *SRE with a

value equal to 0.

At IQS Manager

startup, the register

is set to 0.

Advertising