5 single collector flashing kit - 22 – Glow-worm Clearly Solar Vertical In-Roof Collector User Manual

Page 12

Advertising
background image

12

5 Single Collector Flashing Kit - 22

0

- 75

0

Position the collector, protective side uppermost into the

location channel as shown in diagram 5.4.

NOTE: The design is symmetrical and does not have a top or

bottom.

Secure the collector with the clamps and screws provided, see

diagram 5.5.

With regards to the hydraulic system you have chosen, insert

and secure the hydraulic connections, see diagram 5.6.

Insert the collector sensor into the appropriate elbow (flow,

top), see diagram 5.6. The collector sensor is packed with the

Fluropro controller, part no. 0020054960.

Mount the plug with the bleed valve in the opposite top

position.

Connect the collector to the system circuit.

Ensure that all of the following steps have been performed:-

- All the connections have been fixed with securing clips.

- All hydraulic connections laid properly.

- The collector sensor has been connected.

- The collector is connected to a lightning protection device.

- A pressure test.

- All insulation is intact.

NOTE: After initial commissioning and according to the season,

high outside temperature oscillations can cause condensation

in the collector, this is normal.

Fit the side sections to the collector frame, ensure that it is

pushed into place on the collector edge, see diagram 5.7.

Diagram 5.6

15023

Diagram 5.7

14979

SIDE

SECTION

COLLECTOR

Diagram 5.5

14974

CLAMP

SCREW

(No.3)

Diagram 5.4

15026

COLLECTOR

SENSOR

LOCATION

CHANNEL