With regards to the hydraulic system you have chosen, insert

and secure the hydraulic connections, see diagram 7.9.

Insert the collector sensor into the appropriate elbow (flow,

top), see diagram 7.9. The collector sensor is packed with the

Fluropro controller, part no. 0020054960.

Mount the plug with the bleed valve in the opposite top

position.

Connect the collector to the system circuit.

Ensure that all of the following steps have been performed:-

- All the connections have been fixed with securing clips.

- All hydraulic connections laid properly.

- The collector sensor has been connected.

- The collectors are connected to a lightning protection

device.

- A pressure test.

- All insulation is intact.

NOTE: After initial commissioning and according to the

season, high outside temperature oscillations can cause

condensation in the collector, this is normal.

Fit the side sections to the collector frame, ensure that they

are pushed into place on the upper collector edge, see

diagram 7.10.

Secure the side sections to the roof battens with the supplied

clamps and screws (No. 2) using the supplied Torx bit, see

diagram 7.11.

Slide the intermediate plate from below and between the

collectors, until it is flush with the lower collector edge, see

diagram 7.12.

NOTE: If it’s not possible to mount the intermediate plate

from below (because of dormers, etc.), carefully bend up the

intermediate plate (see inset diagram 7.12), slide the plate

from the top between the collectors and bend it down again.