8 two collector flashing kit - 15 – Glow-worm Clearly Solar Vertical In-Roof Collector User Manual

Page 32

Advertising
background image

32

14975

Diagram 8.4

SCREW

(No.1)

ALIGNMENT

MARK

14969

LOCATION

CHANNEL

ALIGNMENT

MARKS

PIPE

COUPLING

Diagram 8.5

Slide the right front section up to the mark on the left front

section, see diagram 8.4. With six securing screws (no.1),

screw the right front section to the roof batten using the

supplied Torx bit.

Position the collector panel protective side uppermost into the

location channel as shown in diagram 8.5.

NOTE: The design is symmetrical and does not have a top or

bottom.

Insert the pipe couplings into the hydraulic socket connection.

The pipe coupling should be inserted up to the stop.

Place the next collector into its position as previously

described, then push the collector, ensuring engagement of

the pipe coupling, see diagram 8.6, and align with the marks

on the flashing.

With the screws (No.3) and clamps and Torx bit supplied,

secure to the roof battens, see diagram 8.7.

For securing between collectors the inner clamp should be

secured as shown and grip both collector edges, see diagram

8.8

Diagram 8.6

14951

RETAINING

CLIP

Diagram 8.7

14974

INNER CLAMP

SCREW

(No.3)

8 Two Collector Flashing Kit - 15

0

- 22

0

LOCATION

CHANNEL

Diagram 8.8

15195

INNER CLAMP

SCREW

(No.3)

Advertising