INSTALLATION

8 electrical connections

The electrical connection of the room thermostat

must be made only by a qualified engineer.

The radio receiver must be connected to the

eBUS connector.

8.1

Main board

1

2

3

30 mm max.

Legend

1 Connector

2 electrical wires

3 Insulation

When connecting electrical cables to a connector of the main

board:

• Maintain a maximum distance of 30 mm between the

connector (1) and the insulation (3).

8.2

Connecting the radio receiver

The location of the EBUS terminal block varies

according to the heating system. It is always

identified by having "BUS" written on it.

• Use the EBUS connection cable provided.

• Cut the EBUS connection cable to the length necessary for

your installation.

Case n°1 - radio receiver on the control box

• Connect the EBUS cable, following the order of operations

from (A) to (F).

A

B

24

V

C

1

2

3

Legend

1 Access for 24 V connection

2 Control box

3 Pre-cut part of control box unit

• Open (A) the access for the 24 V connection (1).

• Cut (B) the pre-cut part (3) of the control box unit (2).

• Remove (C) the pre-cut part of the control box unit (2).

D

RT 24V

T° ext

BUS

BUS

24 V

F

E

1

2

3

6

5

4

Legend

1 ebUS connecting cable

2 Link the connection terminal block on the room thermostat

3 ebUS terminal block for the main board

4 Control box unit

5 Radio receiver connector

6 Pre-cut part of control box unit

• Do not remove the link from the terminal block connecting

the room thermostat to the main board.

• Pass (D) the EBUS cable (1) through the cable passage

created by removing the pre-cut part (6).

• Connect (E and F) the EBUS cable (1) to the radio receiver's

connector (5) and to the EBUS terminal block on the main

board (3). There is no polarity that must be respected.