Installation – Glow-worm Climapro2 RF User Manual

Page 15

Advertising
background image

0020094586_01 - 08/10 - Glow-worm

- 13 -

INSTALLATION

10.6 Cooling function

Menu

This menu lets you:

Activate or deactivate the cooling function

in the end user menu.

Enable or disable the cooling program in

the end user menu.

10.6.1

Activate or deactivate the cooling function

This function allows the user to activate or deactivate the

cooling menu.

• From the installer menu (see access to the installer menu) >

select on the screen >

cooling > on/off

• Press

to highlight your choice (activate or deactivate)

and press the button

to confirm.

10.6.2

enable or disable the cooling program

The cooling function must be activated before it can

be programmed.

This function makes it possible to allow the user to program

cooling.

• From the installer menu (see access to the installer menu) >

select on the screen >

cooling > enable program

• Press

to highlight your choice (enable or disable) and

press the button

to confirm.

10.7 Options

Menu

This menu lets you:

Configure the wireless outdoor

sensor:

- for correcting the measured

outside temperature,

- for choosing the heating curve (see

the instructions for the wireless

outdoor sensor).

Adjust the date and time
Choose the language
Enter the telephone number that will be

displayed in after-sales service messages.
Display information: zone, type and

software version for the room thermostat

10.7.1

Outdoor sensor settings

Correcting the outside temperature

This function lets you rectify the temperature measured by

the room thermostat (by +/- 5 °C with a step of 1 °C - factory

setting: 0).

• From the installer menu (see access to the installer menu) >

select on the screen >

settings > outdoor sensor settings

>

outside T

O

correction

• Increase or reduce with the

buttons to display the

desired correction and validate with button

.

Choosing the heating curve (gradient)

This function lets you choose the heating profile (value

adjustable between 0.2 and 4 - factory setting: 1.6).

• See the installation manual for the outdoor sensor.

• From the installer menu (see access to the installer menu) >

select on the screen >

settings > outdoor sensor settings

> select

heating curve

Advertising