Installation – Glow-worm Climapro2 RF User Manual

Page 11

Advertising
background image

0020094586_01 - 08/10 - Glow-worm

- 9 -

INSTALLATION

Case n°2 - radio receiver in the control box unit

A

RT 24V

T° ext

BUS

BUS

24 V

B

1

2

3

5

4

Legend

1 ebUS connecting cable

2 Link for the connection terminal block on the room thermostat

3 ebUS terminal block for the main board

4 Control box unit

5 Radio receiver connector

• Do not remove the link from the terminal block (2) connecting

the room thermostat to the main board.

• Connect (A and B) the EBUS cable (1) to the radio receiver's

connector (5) and to the EBUS terminal block on the main

board (3). There is no polarity that must be respected.

Case n°3 - radio receiver outside the appliance

1

2

3

Legend

1 ebus and 0V connection

2 Cable strain relief

3 Connector for the radio receiver

• Do not remove the link from the terminal block for connecting

the main board’s room thermostat.

• Connect the EBUS cable to the radio receiver connector

and the EBUS and 0V connection in the electrical cartridge.

Polarity is not important.

8.3

Pairing (recognition)

8.3.1

The room thermostat delivered with a radio

receiver

The pairing between the room thermostat and its radio receiver

requires no action on your part. It is carried out in the factory.

8.3.2

The radio receiver with wireless outdoor

sensor

Pairing between the external temperature probe and the radio

receiver is possible (see the installation manual for the external

probe).

The radio receiver can be paired with the wireless outdoor

sensor (see the outdoor sensor installation manual).