Maintenance, 13 fault diagnosis – Glow-worm Climapro2 RF User Manual

Page 18

Advertising
background image

0020094586_01 - 08/10 - Glow-worm

- 16 -

MAINTENANCE

MAINTeNANCe

13 fault diagnosis

In case the signal is lost between the room

thermostat and the radio receiver (e.g. : batteries

exhausted), the heating system uses its own

functioning settings.

Faults described in this chapter should be carried

out by a qualified engineer and if needed by the

After Sales Service.

You will find a list of certain error codes in the user manual.

5

4

3

2

1

Legend

1 Radio receiver

2 Cover for radio receiver

3 Red LeD

4 Radio receiver circuit board

5 Green LeD

In the event of a problem:

• Check the error messages in the room temperature

thermostat's display zone

• Remove the cover (2) from the radio receiver (1) to see the

2 LEDs.

• Check the state of the 2 LEDs (green (5) and red (3) located

on the electronic board (4) in the radio receiver.

Radio

receiver

Cause

Solution

Green LED

off

Red LED

off

- Failure of electrical

supply

- Defective EBUS

connection cable

• Ensure that there is

no interruption to the

electricity supply and that

the appliance is properly

connected and turned on.

• Check the electrical

connection between the

receiver and the appliance.

Red LED

switched

on

- Appliance fault

- Radio signal

transmission error

- EBUS communications

error

- Defective radio

transmitter or receiver

- EBUS connecting

cable defective

• Check that:

- The appliances functioning

status is correct

- The room thermostat

batteries are properly

installed in their

compartment

- The battery polarity is not

reversed

- The batteries are not

exhausted. If so, replace with

new batteries.

• Check the electrical

connection between the

receiver and the appliance.

• Check the radio

communication between the

thermostat and the receiver.

Advertising