8 Mounting the boiler

7404

Diagram 8.12

7307

Diagram 8.13

7306

Diagram 8.14

FAN

FLUE
DUCTING

FLUE
CONNECTING
SLEEVE

Push
to fit

FAN

FLUE
CONNECTING
SLEEVE

SECURING
SCREW

RETAINING
LIP

FLUE
DUCTING

FLUE
CONNECTING
SLEEVE

FLUE
COLLECTOR

RETAINING
LIP

FAN
(Push up
to fit)

AIR
PRESSURE
TUBE (2)

ELECTRICAL
CONNECTIONS

7305

CLEAR

RED

Make sure that the ductings do not slope down towards the
boiler.

Remove the fan from the flue collector, secured with a screw
and retaining lip.

Fit the flue connecting sleeve onto the fan, see diagram 8.12.

Fit the fan to the flue ducting, Holding it up in position fit the flue
collector, see diagram 8.13.

Secure the fan to the flue collector with the securing screw and
retaining lip, see diagram 8.14.

Fit the electrical connections and air pressure tubes to the fan.

Refit the combustion chamber panel.

Make the outer wall weatherproof. A Flue Collar Kit Part No.
443286 is available.