Maintenance, Diagnostic codes - level 1 installer access – Glow-worm Flexicom cx User Manual

Page 39

Advertising
background image

0020107232_03 - 12/14 - Glow-worm

MAINTENANCE

- 39 -

DIAGNOSTIC CODES - LEVEL 1 Installer Access

14512

To enter the diagnostics menu follow the procedure below:-

Press and hold the ‘MODE’ and ‘+’ buttons for approx 5 seconds until the screen changes. Use the ‘+’ or ‘-’ button to select the

number 96, this is the password. Hold the ‘MODE’ for approx 5 seconds when 96 is selected, when the screen changes release

the button. The screen will flash between ‘L1’ and a number. ‘L1’ indicates you have level 1 access, the number indicates

the diagnostic number below. Use the ‘+’ and ‘-’ to cycle through the selections below. To select a diagnostic number press

the ‘MODE’ button when the correct number is selected. The display will show the parameter value of the diagnostic number

selected. To return to the diagnostic number selector simply press the ‘MODE’ button. To change the parameter use the + or

- buttons. Once the value has been changed it must be saved by holding the ‘MODE’ button for approximately 5 seconds. This

will return to the diagnostic number selector.

Diagram 13.8

Indicates read and write function - all other diagnostics are read only