General data – Glow-worm Hideaway 100BF User Manual

Page 5

Advertising
background image

5

221764B

General Data

A

B

C

D

E

F

G

H

J

K

L

M

N

P

mm

474

214

558

294

359

533

3

300

445

121

156

664

398

398

in.

18

11

/

16

8

1

/

2

22

11

1

/

2

14

1

/

8

21

1

/

8

11

3

/

4

17

1

/

2

4

3

/

4

6

1

/

8

26

1

/

8

15

5

/

8

15

5

/

8

RANGE RATING

NOMINAL

kW

HEAT INPUT
(GROSS)

Btu/h

33.18

35.00

36.78

113,200 119,500 125,500

min

medium

max

BURNER

mbar

SETTING
PRESSURE

in.w.g

(HOT)

9.3

10.5

11.7

3.7

4.2

4.7

NOMINAL

kW

HEAT
OUTPUT

Btu/h

26.38

27.84

29.31

90,000

95,000 100,000

205748

INJECTOR

GENERAL DIMENSIONS - given in millimetres (Approx. inches)

Diagram 1.1

1071

Refer to BOILER CASING

HEIGHT diagram

M

D

C

C

L

A SPECIAL TOP CASING

TO SUIT 600mm (23

5/

8

in.)

WORKTOPS IS AVAILABLE

WATER CONNECTIONS

Rc1 (1in. B.S.P.T.)

WATER CONNECTIONS Rc1 reduced
with DISTRIBUTOR TUBE to
Rc

3/

4

(

3/

4

in. B.S.P.T.) (pumped return)

GAS CONNECTION

Rc

1/

2

(

1/

2

in. B.S.P.T.)

F(MIN.)

L

H

A

L

C

B

N

P

C

L

E

J

K

G(MIN.)

G(MIN.)

Important Notice

This boiler is for use only on G20 gas.

Wherever possible, all materials, appliances and components
used shall comply with the requirements of applicable British
Standards.

Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

1.1 Data

Weight of boiler 147.0kg (324lb)

Water content

11.7litre (2.57gall)

Gas connection

Rc1/2

1

/

2

inBSP

Water connection

Rc1 1 in BSP

Electrical supply 230V ~ 50Hz fused 3A

Burner

Aeromatic (2 off)

All dimensions are given in millimetres, except as noted.

The Seasonal Efficiency Domestic Boilers UK (SEDBUK)
is 73.0%.

The value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

1.2 Range Rating

This boiler is range rated and may be adjusted to suit individual
system requirements.

The Tables give the appropriate settings and ratings.

The boiler heat input is factory preset to its maximum rating.
This should be adjusted to suit individual system requirements.

The arrow indicator, from the loose items pack, should be stuck
on the data label to indicate the setting.

1.3 Sheet Metal Parts

WARNING. When installing or servicing this boiler, care should
be taken to avoid any possibility of personal injury when
handling sheet metal parts.

1.4 Statutory Requirements

The installation of this boiler must be carried out by a competent
person in accordance with the relevant requirements of the
current issue of:

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations, The Building
Regulations, The Bye-laws of the Local Water Company, The
Building Standards (Scotland) Regulations, (applicable in
Scotland), The Health and Safety at Work Act, Control of
Substances Hazardous to Health, Electricity at Work Regulations
and any applicable local regulations.

Detailed recommendations are contained in the current issue of
the following British Standards and Codes of Practice:

BS6798, BS5440 Part 1 and 2, BS5546, BS5449 Part 1,
BS6700, BS6891, BS7478, BS7593, BS7671.

Manufacturers instructions must in not be taken as overriding
statutory requirements.