4 Installation

General Installation Notes

The appliance pack contains :-

Boiler.

Casing panels, packed seperately.

Loose items fittings pack, see list in pack.

The chimney flue adapter with flue extension is supplied
seperately.

Before installation of the boiler make sure that the location
selected is in accordance with the requirements of Section 1.8.

4.1 Unpacking

The boiler casing panels are packed separately within the main
carton and are designed to enable gas and water connections
to be made before fitting the casing panels.

The casing brackets, flue restrictor, distributor tube and other
loose items, are in the fittings pack.

IMPORTANT. With regards to the Manual Handling Operations,
1992 Regulations, the following operation exceeds the
recommended weight for one man lift.

4.2 Water Connections - Gravity Domestic and
Pumped Heating

Fit suitable fittings into the boiler tappings, see diagram 4.1.

Make sure that all pipes are taken backwards and will clear the
casings.

Heating flow: Any one of the four upper connections may be
used.

Domestic flow: Any one of the three remaining upper connections
may be used.

Heating return: The water distributor tube must be fitted into
either of the front lower connections on all installations, see
diagram 4.2. This tube is in the fittings pack.

Domestic return: Any one of the three remaining lower
connections may be used for the gravity domestic hot water
return.

Fit plugs into any unused boiler tappings.

4.3 Water Connections - Fully Pumped
Systems

Fit suitable fittings into the boiler tappings as required, see
diagram 4.3. Make sure that all pipes are taken backwards and
will clear the casings.

It is important that all connections are made as shown in
diagram 4.3.

Fit the water distributor tube into the return connection, see
diagram 4.2. This tube is packed in the fittings pack.

Fit plugs into any unused boiler tappings.

Diagram 4.1

WATER CONNECTIONS - GRAVITY
DOMESTIC, PUMPED HEATING

ALTERNATIVE
HEATING
RETURN
With distributor
tube (not shown)

ALTERNATIVE
HEATING OR
DOMESTIC
HOT WATER
FLOW

GRAVITY
DOMESTIC
RETURN TO
ANY OF THE
3 REMAINING
LOWER CONNECTIONS

9859

DISTRIBUTOR TUBE

Diagram 4.2

1277

UPPER
MARKER

DISTRIBUTOR
TUBE
must be in
pumped return
connection

UPPER MARKER
must lie between the
two outer NOTCHES

Diagram 4.3

WATER CONNECTIONS FULLY
PUMPED SYSTEMS

9859

ALTERNATIVE
FLOW
POSITIONS

ALTERNATIVE
RETURN
POSITIONS
With distributor
tube (not shown)